Free Dell DCPPE-200 Exam Dumps Questions & Answers
| Exam Code/Number: | DCPPE-200Join the discussion |
| Exam Name: | Dell PowerEdge Professional Exam |
| Certification: | Dell |
| Free Question Number: | 93 |
| Publish Date: | Nov 17, 2026 |
| # of views: | 3628 |
|
|
|
An engineer is migrating an existing server node from an M1000E to a VRTX chassis. An error message appears during POST. The system will continue to boot, but can NOT see any of the chassis shared storage or PCIe devices mapped to the server slot. The engineer has already removed the original fabric interfaces in mezzanine slot B and C from the original system configuration.
Which action must the engineer complete to allow the node to see chassis storage and mapped PCIe devices?
An engineer needs to put chassis switches on a LAN that has already been configured for latency sensitive applications and to enable lossless links.
How should the engineer accomplish this?
A customer has five VRTXs in a chassis group that they need to disband. The engineer disbands the chassis group from the group leader, but a networking interruption prevents two of the VRTXs from getting the signal to leave the group.
What should the engineer do to finish disbanding the chassis group?
An engineer is inventorying a newly arrived M1000e shipment that will be used for a virtual environment. The inventory includes the following:
Blade Server Enclosure, M1000E, PowerEdge - qty 1
Power Supplies 2700W High Efficiency - qty 3
Redundant Chassis Management Controller- qty 1
Power Cords, QTY3, 8FT, C19/C20 for M1000E Server Blade Chassis - qty 2 Cat5e Patch Cable 1000Mb - qty 2 Dell Force10 MXL 10/40 GbE DCB Blade Switch - qty 2 QSFP+ 40GbE Module, 2 port, Hot Swap - qty2 SFP+ 10GbE Module, 4 port, Hot Swap - qty 2 SFP+ to SFP+, 10GbE, Copper Twinax Direct Attach cable, 3 Meters - qty 8 The chassis power will be set for grid redundancy. The top of rack switches are 10Gb and the management switch is 1000 Base-T. What is missing from this inventory that is needed to accomplish this task?
An engineer is installing an M1000e chassis and connecting it to the network in the top of rack (ToR) switch.
The entire company's infrastructure is on a single subnet configured as follows.
- IPs10.0.1.0/24
- Gateway10.0.1.1
- DNS10.0.1.3
- DHCP10.0.1.4
- OS IPs10.0.1.10-99
The engineer configures the CMC to use IP 10.0.1.100 and the iDRACs to use the next 16 IPs.
The customer notices the CMC and the iDRAC are having intermittent connectivity issues. The following troubleshooting steps have been completed:
- Replaced cables from CMCs to ToR
- Failed over CMC
- Configured and tried different ports in ToR
- Connected the laptop directly to the CMC
Direct connection to the CMC does NOT show any connectivity issues.
What should be done to fix the connectivity issues?