Location and Transportation Credit, Reduced Parking Footprint calculations must include
Correct Answer: D
This option requires the project to include all parking spaces that are outside the project boundary but are used by the project occupants, visitors, or customers in the calculations for the reduced parking footprint credit1. This option ensures that the project accounts for the total parking demand and supply associated with the project, regardless of the location of the parking spaces2.
Question 127
What supporting material is required for all LEED Building Design and Construction projects in order to document Location and Transportation Credit, Bicycle Facilities for the bicycle network?
Correct Answer: C
The Location and Transportation Credit, Bicycle Facilities, requires the project team to provide a vicinity map that shows the bicycle network, the route and the distance along the network to eligible destination(s) for all LEED Building Design and Construction projects. The vicinity map is a supporting material that demonstrates that the project site is within a 200-yard (180-meter) walking distance of a bicycle network that connects to at least one of the following: diverse uses, public transportation, recreation facilities, or schools1. The vicinity map must also show the scale and the north arrow, and indicate the project site and the eligible destination(s) 2. The photographs of bicycle network signage and directional signposts, the photographs of the installed bicycle storage and shower facilities, and the manufacturer specifications for the chosen bicycle storage facilities are not required for the bicycle network, but for the bicycle storage and shower facilities.
Question 128
A construction manager is looking for a project management tool that offers energy management strategies, benchmarking software tools for buildings, and product procurement guidelines. Which of the following is recognized by U.S. Green Building Council to assist them?
Correct Answer: C
ENERGY STAR® (C) provides tools recognized by the U.S. Green Building Council (USGBC) that assist with energy management strategies, benchmarking, and procurement guidelines. ENERGY STAR offers resources for energy performance benchmarking, operational efficiency, and product standards, which help project managers optimize energy use in line with LEED requirements. Green Seal (A) and SCAQMD (B) focus on materials and emissions, while SMACNA (D) provides guidelines for air quality management.
Question 129
The WaterSense label or local equivalent requirement in Water Efficiency Prerequisite, Indoor Water Use Reduction ensures that eligible newly installed plumbing fixtures will
Correct Answer: B
The WaterSense label or local equivalent requirement in Water Efficiency Prerequisite, Indoor Water Use Reduction ensures that eligible newly installed plumbing fixtures will be both water efficient and high performing. The WaterSense label is a voluntary program by the U.S. Environmental Protection Agency (EPA) that identifies and promotes water-efficient products that meet EPA's specifications for water efficiency and performance. The label applies to tank-type toilets, water-using urinals, private lavatory faucets, and showerheads. For projects outside the U.S., local equivalents may be used if they meet the same criteria as WaterSense or are listed on the USGBC website. The label does not imply that the fixtures are LEED compliant, comply with mandatory federal government regulations, or comply with all international plumbing system requirements. Reference: Water Efficiency Prerequisite: Indoor Water Use Reduction in LEED BD+C: New Construction v4.1 - LEED v4.11 What is the WaterSense Label and How Does it Apply?2 LEED QUALIFICATION GUIDE - v43 WaterSense Labeled Homes4
Question 130
Which of the following must be included in the Sustainable Sites Credit, Site Assessment?
Correct Answer: C
The correct answer is C. Proximity of vulnerable populations to major sources of air pollution. According to theLEED V5.1 Reference Guide for Building Design and Construction, the Site Assessment credit requires projects to conduct and document a site inventory and analysis that covers the following topics1: Topography Hydrology Climate Vegetation Soils Human use Human health effects The human health effects topic includes identifying the proximity of vulnerable populations, such as children, elderly, or low-income residents, to major sources of air pollution, such as highways, power plants, or industrial facilities.This information can help the project team design strategies to minimize the exposure of occupants and visitors to harmful pollutants and improve the indoor and outdoor air quality of the project1. The other options are not required for the Site Assessment credit, although they may be relevant for other credits or prerequisites.A targeted Brownfield remedy plan is required for the Brownfields Remediation credit, which applies to projects located on sites contaminated by past uses1.A historic preservation plan to include neighboring properties is not required for any LEED credit, although projects that involve historic buildings ordistricts must comply with local regulations and standards for preservation1. The surrounding density within a 1/4 mi.(0.40 km) radius of the project boundary is not required for the Site Assessment credit, but it is used to calculate the points for the Surrounding Density and Diverse Uses credit, which encourages projects to locate in areas with high levels of existing development and mixed land uses1.