Question 96
When different routes are used for client-side 1 + 1 protection, the working wavelength and protection wavelength cannot use the same wavelength.
Question 97
For the MSTP equipment, the pass-through mode is used for VC-4 services by default, and the termination mode is used for VC12/VC3 services by default.
Question 98
In the case of the OptiX OSN equipment, when the standby board is normal, which of the following operations does not cause the active/standby switching of the cross-connect board or clock board?
Question 99
Which of the following protection schemes require the APS protocol?
Question 100
A, C are the WDM OTM stations, and B is the relay station. When the transmission direction of the A to B stations is interrupted, the Wavelength side of the B-stack OTU relay board reports the R_LOS emergency alarm and runs the processing to the upstream A.
The station side OTU2_BDI secondary alarm. At the same time, the alarm continues to be transmitted to the downstream station of the B station. After the alarm is processed at the C site, the ODU2_PM_AIS minor alarm is reported on the WDM side of the C-site OTU, and the ODU2_PM_BDI secondary alarm is transmitted back to the upstream station A.