Question 106
After the PWE3 service is successfully deployed, what is the deployment status of the PWE3 service displayed?
Question 107
When creating an electric layer path, one RX/TX port can only establish a connection with one optical channel of the clientLP port.
Question 108
The single-fiber bidirectional WDM system uses only one fiber to transmit optical signals in both directions simultaneously. The optical signals in both directions should be arranged at different wavelengths.
Question 109
For ODUk SNCP protection, if the punch-through site is an electrical relay station, the SCP type is recommended to be configured as SC/I when configuring protection.
Question 110
In the scenario where the non-convergence OTU processes OTN standard signals, both A and B are WDM sites. After receiving the OTUk_TIM alarm on the client side, the OTU board at station A sends the OTUk_BDI alarm to the upstream. When the TIM follow-up action is disabled, the alarm is no longer transmitted to the downstream. When the TIM follow-up action is enabled, an SF event is generated. The WDM side of the OTU board at station B reports the ODUk_PM_AIS alarm, and the ODUk_PM_AIS alarm is transmitted downstream. The client equipment reports this alarm. After the WDM side of the OTU board at station B receives the OTUk_TIM alarm and the TIM follow-up action is disabled, the alarm is no longer transmitted to the downstream. When the TIM follow-up action is enabled, an SF event is generated. After the client side of station B processes the SF event, the client equipment reports the ODUk_PM_AIS alarm.